DC brushless motor, control precision, smooth; multi-channel infrared sensor technology to detect movement, to prevent non-standard traffic and traffic safety; sound and light alarm function, and guard against unauthorized access or non-standard personnel traffic; modular design, easy to installation and transportation, maintenance; off automatically open the gates, and ensure that fire safety; prevailing direction of the software settings;
Features:
A traffic model: 1, two-way controlled; 2, has been controlled, the other to prohibit; 3, two-way prohibited
4, has been controlled, the other to the free passage; 5, two-way free passage;
6, has forbidden, and the other to the free passage
B Control: 1, card reader, or buttons to open, 2, free passage, 3, closed to traffic, you can set by software
C gate opening memory settings: You can set the software or DIP switch can access the memory.
D status is set to pass: You can access state is set to normally open or normally closed, normally open state, the channel has been in open status, receipt of a valid signal, the officers must pass a specified period of time, out the alarm, When the illegal passage of time immediately locked and unlocked through the reset button; in the normally closed state, the gates had been locked, when traffic was normal, the gates open, people pass within a specified time, otherwise the gate opportunities closed again, the state need to record a variety of abnormalities.
E. Effective access time settings: you can set the channel gate open time, access is within the time prescribed normal, if not pass within the specified time, the gates close automatically, and record the exception.
Effective access time can be set to 5-255 seconds, default is 10 seconds.
F. Limit setting: When staff do not need to pass in one direction, through the state set up after passage in the direction against officers;
G. Counter clear: when given a clear directive, the counter can be cleared.
H. gate time setting switch: gate according to the time the switch is set to demand more files, each file at different speeds, on behalf of switching gates at different times. Value is :1-3 seconds. The default is 1.5 seconds.
I. mandatory switch gate: The directive may require the arm to open, and through instruction forced to close;
J. LCD welcoming settings: You can set the welcome message on the LCD, up to 8 characters, setting is completed, the first line of the LCD display. The second line shows the normal passage of persons.
K. mains failure gate opening settings are: gate opening set when a mains failure, mains failure, the gate is open; When not setting, is the backup battery is empty before opening;
L. time and according to the size of the dynamic flow of people to set the time switch channel gate; example, we set a number of group time, when the 7-9AM set to peak time, gate opening time can be set to 1.2 seconds, while for other time, the gate opening time of 2 seconds;
M. time to download settings: pass card to open the door the next time period;
N. Time Set: Set the time of the pedestrian access hardware;
All of the above parameters are set through the PC, and can be read by software parameters are set. Which set the limit, the counter is cleared to set, forced switch gates were set by instruction.